Standards
ASTM E23, ASTM E74 (Class AA), ISO 148
Ultimate User-Friendliness
Leading Dependability and Reliability
Strict Compliance with Industry Standards
Stocked Consumables and Spares
Trusted After Sales Technical Support
Lifetime Product Support Advantage
Description
The NGT Series Low Temperature Chamber is designed to condition Charpy impact specimens at controlled sub-zero temperatures prior to testing. It cools specimens uniformly and maintains a stable setpoint to support consistent, repeatable results.
Available conditioning targets include -30°C, -60°C, -80°C, -100°C, and -196°C, depending on the selected model.
The system is engineered around thermal balance and circulation to help minimize temperature gradients between specimens and across the chamber volume. A high-precision self-adjusting controller and platiniridium sensor provide accurate monitoring and straightforward operation.
For cooling performance across the full range, the series uses two proven approaches. NGT-60 and NGT-80 rely on compressor-based refrigeration for stable low-temperature conditioning. For extended ultra-low capability, NGT-100 and NGT-196 use liquid nitrogen cooling to reach and maintain the lowest temperature setpoints.
Typical Applications
The NGT Series is used in materials testing labs and quality control environments that perform low-temperature Charpy impact testing, where specimens must be conditioned to a defined temperature before being transferred to the pendulum impact tester.
It is commonly applied to metallic materials and alloys evaluated for toughness and brittle-to-ductile transition behavior, including carbon and stainless steels, aluminum alloys, and nickel-based alloys, as well as weld procedure qualification and production lot verification programs.
Technical Specifications
| Parameter |
NGT-60 |
NGT-80 |
NGT-100 |
NGT-196 |
| Cooling method |
Compressor |
Compressor |
Liquid nitrogen |
Liquid nitrogen |
| Cooling temperature range |
-60°C to +30°C |
-80°C to +30°C |
-100°C to +30°C |
-196°C to +30°C |
| Temperature control accuracy |
≤ ±0.5°C |
≤ ±0.5°C |
≤ ±0.5°C |
≤ ±0.5°C |
| Instrument resolution |
0.01°C |
0.01°C |
0.01°C |
0.01°C |
| Cooling medium |
Ethanol or other non-freezing solution |
Ethanol or other non-freezing solution |
Ethanol or other non-freezing solution |
Ethanol or other non-freezing solution |
Request a Quote
Need help selecting the right NGT model or confirming specifications for your Charpy testing workflow? Our team can answer technical questions and recommend the best configuration for your required temperature range.
Request an online quote or contact us with your details, and we’ll get back to you as quickly as possible.