Impact Specimen Cooling and Heating Temperature Chamber – GenChamber

Trust
  • Impact Specimen Cooling and Heating Temperature Chamber – GenChamber
  • Impact Specimen Cooling Chamber
  • Impact Specimen Cooling and Heating Temperature Chamber – GenChamber
  • Close-up of the NextGen impact specimen cooling and heating temperature chamber with stainless-steel bath and digital control panel beside the impact tester.
  • NextGen impact specimen cooling and heating temperature chamber shown beside a pendulum impact tester for Charpy and Izod specimen conditioning and impact testing.
  • Angled view of the NextGen impact specimen cooling and heating temperature chamber positioned beside a pendulum impact tester for conditioned Charpy and Izod impact testing.
  • Touchscreen control panel of the NextGen impact testing system displaying swing period settings for Charpy and Izod impact testing.
  • Close-up of the heated chamber interior with a stainless-steel specimen basket inside the NextGen impact specimen cooling and heating temperature chamber.

Standards

Description

The Impact Specimen Cooling and Heating Temperature Chamber – GenChamber is a high-performance dual-function system engineered for precise temperature conditioning of Charpy and Izod impact specimens. Designed to meet the requirements of ISO 148-1 and ASTM E23, this chamber supports both low-temperature soaking and high-temperature stabilization for metallic materials prior to impact testing.

The low-temperature mode uses an advanced compressor-based refrigeration system combined with thermal equilibrium and circulating stirring mechanisms, delivering automatic cooling and uniform temperature control down to -80°C. This ensures consistent preparation of impact notch specimens and supports repeatable, reliable test results. Built-in safety protections guard against overheating and overcurrent conditions. Additionally, an integrated alarm notifies the user when the target temperature is reached, guaranteeing precise timing for specimen preparation.

The high-temperature function features a durable stainless-steel electric heating system with forced air circulation and internal ventilation for uniform heat distribution. The system is equipped with PID temperature control and offers high-resolution monitoring with a 0.1°C display accuracy, maintaining stable conditions throughout the heating process. A centrifugal fan ensures continuous airflow and temperature uniformity, meeting industry-standard temperature gradient requirements.

This temperature conditioning chamber is ideally suited for materials testing laboratories, research and development facilities, and quality control departments that require consistent and reliable preparation of Charpy and Izod impact test specimens.

Technical Parameters

Model GenChamber
Range of Control Temperature Low temperature: +30℃ to -80℃ (ambient temperature ≤ 25°C) High temperature: +30℃ to 100℃ (ambient temperature ≤ 25°C)
Temperature Control Accuracy Low temperature: ≤ ±0.5°C High temperature: < ±1°C
Display Resolution 0.1°C
Cooling Speed +30°C to 0°C: approx. 2°C/min 0°C to -20°C: approx. 1.5°C/min -20°C to -60°C: approx. 1°C/min -60°C to -80°C: approx. 0.7°C/min
Heating Speed +20°C to +50°C: approx. 2°C/min +50°C to +100°C: approx. 3°C/min
Working Area (L × W × H) Low Temperature Chamber: 5.9 × 5.5 × 4.7 in (150 × 140 × 120 mm) High Temperature Chamber: 5.9 × 5.5 × 4.7 in (150 × 140 × 120 mm)
Specimen Capacity 60–120 specimens (Standard size: 10 × 10 × 55 mm)
Outer Dimensions (L × W × H) 25.6 × 20.0 × 29.9 in (650 × 510 × 760 mm)
Timer 1 to 99 minutes, 1-second resolution
Cooling Medium Cooling chamber: Ethyl alcohol (≥ 99.5% purity recommended) Heating chamber: Air
Stirring Motor Power 23 W
Power Supply Single-phase, 110 V, 60 Hz, 2.5 kW
High-Temperature and Low-Temperature Chambers of the GenChamber System
High-Temperature and Low-Temperature Chambers of the GenChamber System

Standard Configuration

Model GenChamber
Main Unit One set
Cooling Compressor One set
Stainless Steel Heating Pipes One set
High-Precision Intelligent Temperature Controller One set
Stainless-Steel Inner Chamber Corrosion-resistant and anti-aging
Sample Baskets 3 pieces for the high-temperature chamber 3 pieces for the low-temperature chamber
Power Transformer Included (110V input to 220V output)

FAQs

The GenChamber is a temperature conditioning chamber developed for preparing Charpy and Izod impact specimens before testing. It combines low-temperature soaking down to –80 °C with high-temperature stabilization up to +100 °C, allowing materials to be tested under a full range of thermal conditions.

This system is widely used in materials testing laboratories, R&D facilities, and quality control departments. Conditioning specimens before fracture provides reliable data on how metals and other materials behave in both extreme cold and elevated heat, supporting compliance with standards such as ISO 148 and ASTM E23.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber functions as a dual-purpose system that prepares Charpy and Izod specimens through both cooling and heating cycles. In low-temperature mode, a compressor-based refrigeration system combined with an ethanol cooling medium and stirring mechanism lowers specimens to as cold as –80 °C. In high-temperature mode, stainless steel heating elements with forced air circulation raise specimens up to +100 °C.

The principle is straightforward: specimens are brought to a defined thermal state before impact testing, ensuring that the fracture behavior reflects actual service conditions. By delivering precise and uniform temperature conditioning, the GenChamber allows laboratories to produce consistent and repeatable impact test results across different batches and materials.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber is manufactured in line with ISO 148, which sets the procedure for Charpy impact testing of metallic materials, and ASTM E23, the widely used American standard for notched-bar impact testing. It also complies with ASTM E74 (Class AA), covering calibration procedures for impact testing equipment to ensure traceable accuracy.

Together, these standards form the backbone of international impact testing practice. Compliance means the chamber can be used in laboratories worldwide without modification, supporting industries that require verified test results for product certification, regulatory approval, and material research.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber is built for preparing Charpy and Izod impact specimens before testing. It accommodates the standard size of 10 × 10 × 55 mm, which is commonly used across international standards.

The chamber is primarily applied to metallic materials, conditioning impact notch samples to either low or high temperatures before they are fractured under a pendulum impact tester. By stabilizing specimens in controlled environments, the GenChamber helps laboratories achieve repeatable results that align with ISO 148, ASTM E23, and related methods.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber offers controlled temperature transitions tailored for impact specimen preparation. In cooling mode, the rate varies with the target range: about 2 °C/min from +30 °C to 0 °C, 1.5 °C/min from 0 °C to –20 °C, 1 °C/min from –20 °C to –60 °C, and around 0.7 °C/min from –60 °C to –80 °C.

In heating mode, the system raises the temperature at approximately 2 °C/min between +20 °C and +50 °C and 3 °C/min between +50 °C and +100 °C. These controlled gradients help specimens reach equilibrium without thermal shock.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber relies on a compressor-based refrigeration system that works with ethyl alcohol as the cooling medium. A stirring mechanism circulates the liquid continuously, helping specimens reach uniform temperatures without localized cold spots.

This system enables cooling down to –80 °C, with stepwise gradients from ambient conditions. The combination of controlled refrigeration, ethanol circulation, and stirring stability makes the chamber suitable for preparing Charpy and Izod specimens in line with ISO and ASTM low-temperature testing requirements.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber uses a stainless-steel electric heating system paired with forced air circulation to deliver stable and uniform heat. A PID controller regulates temperature changes with high precision, while a centrifugal fan keeps air moving continuously inside the chamber.

This setup prevents localized hot zones and maintains uniform heat distribution across all specimens. The combination of durable heating elements and controlled airflow supports reliable conditioning up to +100 °C, meeting international impact testing requirements.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber is delivered as a complete system with all the main components required for operation. The cooling compressor handles low-temperature conditioning, while the stainless steel heating pipes manage high-temperature cycles. A high-precision intelligent temperature controller is included for accurate monitoring and adjustment.

For handling specimens, the package provides three baskets for the cooling chamber and three baskets for the heating chamber, allowing batch preparation. The unit also comes with a stainless-steel inner chamber for durability and a power transformer for installations where 220 V conversion is needed.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber is equipped with a programmable timer that can be set from 1 to 99 minutes with a 1-second resolution. This feature allows operators to define precise soaking times for both cooling and heating cycles, ensuring specimens remain at the required temperature for the correct duration.

Once the programmed time elapses, the chamber completes the cycle automatically, removing the need for manual monitoring. This automation helps laboratories maintain consistent specimen preparation and reduces the risk of variability between batches.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber includes an integrated alarm system that activates once the target temperature has been reached. This notification alerts the operator that specimens are conditioned and ready for transfer to the impact tester.

The alarm also helps with precise timing, since the interval between reaching the set temperature and starting the impact test is critical for consistent results. By signaling exactly when the chamber is stable, the system reduces guesswork and allows laboratories to follow ISO and ASTM requirements more confidently.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber maintains temperature consistency through a combination of forced air circulation and a centrifugal fan in the heating chamber, along with a stirring motor in the cooling section. These systems keep air and coolant moving continuously, preventing hot or cold spots from forming around the specimens.

This uniform distribution ensures that all samples inside the chamber reach the same thermal state, whether during rapid cooling down to –80 °C or heating up to +100 °C.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber features a 0.1 °C display resolution, giving operators fine control over temperature settings and clear visibility of even small fluctuations. In cooling mode, the system maintains accuracy within ±0.5 °C, while in heating mode, it holds stability within ±1 °C.

This level of precision is supported by the chamber’s PID temperature controller and continuous circulation systems, which distribute cold or hot air evenly across the specimen load. As a result, every sample in the chamber experiences the same conditions.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber runs on a single-phase 110 V, 60 Hz power source with a load capacity of 2.5 kW. This makes it compatible with standard laboratory electrical setups in regions using 110 V mains.

For installations in areas operating on 220 V, a step-down transformer is supplied as part of the standard configuration, so no additional modifications are needed. The system’s electrical design ensures stable performance for both the refrigeration unit and the heating chamber, supporting precise specimen conditioning across the full temperature range.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber can handle between 60 and 120 specimens in a single cycle, depending on how the baskets are loaded. This capacity is based on the standard Charpy and Izod specimen size of 10 × 10 × 55 mm (0.39 × 0.39 × 2.17 in).

Each chamber is equipped with dedicated sample baskets, allowing multiple specimens to be placed securely during heating or cooling. This setup enables laboratories to prepare large batches consistently, which is especially useful for production testing or certification work where many samples must be processed under identical temperature conditions.

Click here to learn more about the product or here to receive a personalized quote.

Both the high-temperature and low-temperature sections of the GenChamber have identical internal dimensions of 5.9 × 5.5 × 4.7 in (150 × 140 × 120 mm). The chambers are built with a stainless-steel inner structure, which resists corrosion and aging even under repeated exposure to extreme conditions.

This working space is designed to hold multiple Charpy or Izod specimens simultaneously, allowing operators to condition entire batches under the same thermal profile. The combination of uniform chamber size and durable stainless-steel construction helps maintain consistent performance while extending service life.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber measures 25.6 × 20.0 × 29.9 in (650 × 510 × 760 mm). Its size allows it to sit comfortably on a standard laboratory bench without the need for dedicated floor space. The relatively compact footprint is an advantage for quality control labs and R&D facilities, where multiple instruments often need to be arranged in a limited area.

Both the cooling chamber and the heating chamber have identical internal working spaces of 5.9 × 5.5 × 4.7 in (150 × 140 × 120 mm), large enough to hold between 60 and 120 standard Charpy or Izod specimens at once. This means a lab can prepare an entire batch of samples under controlled conditions in one cycle, improving workflow efficiency.

Click here to learn more about the product or here to receive a personalized quote.

Regular upkeep of the GenChamber is straightforward but important for consistent performance. The coolant in the low-temperature chamber should be checked and replaced periodically to maintain purity and cooling efficiency. Filters and circulation components need routine inspection to prevent blockages that could disrupt airflow or coolant flow. The stainless-steel inner chamber should be wiped clean after use to avoid residue buildup, especially when specimens release particles. A general inspection schedule covering seals, connections, and sensors helps detect wear early, keeping the chamber dependable during repeated test cycles.

Click here to learn more about the product or here to receive a personalized quote.

After purchasing the GenChamber, customers receive access to a full range of after-sales services. This includes availability of spare parts to keep the system running without long downtime, and technical assistance for troubleshooting, calibration, or operator training. The chamber is supported with stocked consumables such as cooling media and accessories, so replacements are easy to source. These service options help laboratories keep the unit in reliable working condition over many years of use.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber is built with multiple layers of protection to keep both users and specimens safe. It features overheat protection to stop the heating system if the temperature rises beyond set limits, and overcurrent protection to shield electrical components from power surges. The chamber itself has a closed stainless-steel design, keeping the operator separated from the cooling medium and heated space during operation. An integrated alarm system signals when the set temperature is reached or if conditions deviate, giving clear feedback to the user and preventing misuse.

Click here to learn more about the product or here to receive a personalized quote.

The GenChamber includes a warranty that covers both mechanical and electrical components. Mechanical parts, such as door mechanisms, chamber body, and moving joints, are protected under this warranty. Electrical items like the controller, sensors, motor, and display are covered for a defined period as well.

After sales, users have access to technical assistance, spare parts, and service options. These cover repairs, component replacement, and support for calibration or compliance verification.

Click here to learn more about the product or here to receive a personalized quote.

Related Products

Class J - Charpy and Izod Automatic Impact Testing System - 1J - 50J

Class J - Charpy and Izod Automatic Impact Testing System - 1J - 50J

Class J is an automatic Charpy and Izod impact testing system for low-energy impact evaluation of plastics and related materials. It covers 1–50 J for Charpy tests and 1–22 J for Izod tests, with interchangeable pendulums, adjustable spans, controlled striking velocity, and ASTM D6110, ASTM D1822, ISO 179, GB/T 1043, and ISO 9854.1 support for standardized testing.

Read more

Class D Single-Column Charpy Impact Tester – High-Precision Pendulum Testing Machine

Class D Single-Column Charpy Impact Tester – High-Precision Pendulum Testing Machine

Class D is a single-column Charpy impact tester for high-energy pendulum testing of metallic specimens up to 750 J. It supports 150 J, 300 J, 450 J, 600 J, and 750 J configurations, with ASTM E23, ISO 148, and EN 10045 alignment. A heavy cast-iron base, PLC touchscreen, enclosed chamber, motorized hammer return, interchangeable strikers, precision bearings, and optional cooling or automation support safe, repeatable testing.

Read more

Class G Single-Column Charpy & Izod Impact Tester – High-Precision Pendulum Testing Machine

Class G Single-Column Charpy & Izod Impact Tester – High-Precision Pendulum Testing Machine

Class G is a single-column Charpy and Izod impact tester for high-precision pendulum testing of metals and engineering materials. Available in 450 J and 750 J models with optional pendulums down to 150 J, it supports ASTM E23, ISO 148, and EN 10045 workflows. PLC touchscreen control, enclosed safety guarding, motorized hammer return, interchangeable strikers, precision bearings, and optional feeding or cooling improve repeatability.

Read more

Class H - Servo-Motor Dual Column Charpy Impact Tester - 300J, 450J, 600J or 750J

Class H - Servo-Motor Dual Column Charpy Impact Tester - 300J, 450J, 600J or 750J

Class H is a servo-motor dual-column Charpy impact tester for high-volume metal impact testing of hard materials. Available with 300 J, 450 J, 600 J, or 750 J pendulums, it supports ASTM E23, ASTM E1820, ASTM E2298, ISO 148, and EN10045 methods. A rigid cast-iron base, enclosed test area, motorized hammer return, touchscreen display, and optional instrumented striker support accurate, safe testing.

Read more

DWT-1800 Computer Controlled Drop Weight Impact Testing Machine

DWT-1800 Computer Controlled Drop Weight Impact Testing Machine

DWT-1800 is a computer-controlled drop weight impact testing machine for evaluating impact resistance in metal and non-metal materials. Capable of high-energy tests up to 1800 joules and low-energy tests from 3.72 joules, it supports ferritic steel NDT evaluation, conduit testing, tubing, cable hardware, and electrical enclosures. PLC control, touchscreen setup, automated hammer movement, and sensors improve safety and accuracy.

Read more

Triple Specimen Chamber Motorized Charpy Notch Making Machine

Triple Specimen Chamber Motorized Charpy Notch Making Machine

GenNotch 4000UPG is a motorized Charpy notch making machine designed to prepare three impact specimens in one cycle. Built for V-type and U-type notches used in Charpy and Izod testing, it supports ISO 148 and ASTM E23 workflows, with motorized broaching, lubricated operation, controlled travel, and a floor-standing design that helps laboratories produce uniform, standards-ready notched samples.

Read more

Specimen Notching/Broaching Machine

Specimen Notching/Broaching Machine

GenNotch 4000 is a motorized specimen notching and broaching machine for preparing Charpy and Izod impact specimens in metals. Its dual broaching system prepares two samples in one pass, producing V-type and U-type notches with high repeatability. Floor-standing construction, internal lubricating oil circulation, precision broaching knives, standard specimen support, and ASTM E23, ISO 148, EN10045, and DIN 50115 alignment help labs streamline impact preparation.

Read more

Charpy/Izod Notch Verification Projector System NG-NPS-CIS

Charpy/Izod Notch Verification Projector System NG-NPS-CIS

NG-NPS-CIS is a Charpy/Izod notch verification projector for precise inspection of U- and V-type impact specimens. Built for laboratories working to ISO 148, ASTM E23, and GB/T229 requirements, it combines 50× optical magnification, a large Φ200 mm projection screen, integrated digital readout, table rotation, and fine displacement control to help operators confirm notch geometry with clarity and repeatability.

Read more

Impact Specimen Cooling Temperature Chamber – NG-ISCC Series

Impact Specimen Cooling Temperature Chamber – NG-ISCC Series

NG-ISCC Series is a low-temperature chamber for conditioning Charpy impact specimens before pendulum impact testing. Available in -60°C, -80°C, -100°C, and -196°C configurations, it uses compressor refrigeration or liquid nitrogen depending on the model. Uniform cooling, stable setpoint control, ≤ ±0.5°C accuracy, 0.01°C resolution, and ethanol-based cooling media help labs improve repeatability in ASTM E23 and ISO 148 workflows.

Read more