How to Choose the Right Universal Testing Machine for Plastic Testing

Choosing a universal testing machine for plastic testing often sounds easier than it really is. Many buyers start with force capacity, frame size, or the idea of buying extra room for future work. That may seem like a safe decision, but it can push a lab toward a system that costs more, takes up more space, and does not match daily testing needs.

The challenge comes from how broad plastics testing can be. One lab may focus on tensile testing for rigid molded specimens, another may run flexural tests on semi-rigid components, while others may handle thin films, sheets, reinforced plastics, or a wider mix of quality control and development work. Once applications vary, the machine can no longer be chosen by force range alone.

A better decision starts with the actual test program. Standards, specimen geometry, expected loads, grips, fixtures, strain measurement, reporting needs, and day-to-day workflow should define the system before buyers compare frame designs or force ranges. That practical starting point leads into the first selection step: looking at the test program before the frame size.

Short answer
How much force capacity does a UTM for plastic testing need?
Only as much as the test program calls for, and for many routine plastics programs 5 kN or 10 kN already covers the real workload. Capacities such as 30 kN or 50 kN become relevant for reinforced plastics, composites, larger specimens or demanding fixture setups. Standards, grips, fixtures and extensometry should shape the system before the force rating does.

Start With the Test Program, Not the Frame Size

A universal testing machine for plastic testing should be chosen based on the work it will actually handle. Many buying decisions start too early with force capacity, even though capacity is only one part of the system. The test program should come first: the methods being run, the materials being tested, the specimen forms involved, and the level of measurement control the lab needs.

The first point to define is the mix of tests performed most often. For many plastics labs, that means tensile testing to ASTM D638 or ISO 527-2 and flexural testing to ASTM D790 or ISO 178. Some programs also include compression testing under ASTM D695, while thin films and sheets shift the selection path toward ASTM D882. Each method affects specimen style, fixture choice, and the type of measurement the setup must support.

Material range matters just as much. A lab working with rigid molded plastics will not need the same setup as one handling semi-rigid parts, reinforced plastics, films, foams, or a broader development workload. Two labs may both say they do plastic testing while facing very different load levels, gripping conditions, and specimen behavior. A more useful starting point is to define which plastics the lab tests, in what form, and under which standards.

Specimen geometry should be defined at the same stage. A rigid tensile bar, a thin film strip, and a flexural specimen for three-point bending do not call for the same grips, fixtures, or setup. The hardware around the frame should follow the samples the lab actually runs, instead of being added later after the machine has already been narrowed down.

Expected load range still belongs in the discussion, but it should be read in context. Routine plastics work often fits a lower benchtop range, while reinforced plastics or broader mixed-material work may justify more capacity. A higher force rating can be useful, but only when it matches the real demands of the program. On its own, it does not define the right machine.

Measurement requirements can change the decision just as quickly. In some programs, force and break data may cover the main need. In others, strain accuracy and modulus evaluation are a much larger part of the job. In those programs, extensometry and measurement quality should be specified early.

The way the system will be used across the lab also needs to be clear before machine size is discussed. A QC lab may care most about repeatability, setup speed, and simple reporting. An R&D lab may need broader flexibility across methods and fixtures. A production-support lab may prioritize throughput, while a multi-user environment may need a system that is easier to run consistently from one operator to the next.

Let the Test Standard Define the Setup

A plastic UTM should not be chosen as a generic machine first and matched to standards later. In plastics testing, the standard shapes the real buying logic. It affects specimen format, fixture choice, strain measurement, and the level of control the system needs.

Standard Typical Use in Plastics Labs  What It Changes 
ASTM D638  Tensile testing of rigid plastic specimens  Specimen style, grips, extensometry, tensile workflow 
ISO 527-2  Tensile testing of rigid and semi-rigid plastics  Specimen dimensions, strain setup, reporting basis 
ASTM D790  Flexural testing of rigid and semi-rigid plastics  Bend fixture, span setup, modulus workflow 
ISO 178  Flexural testing with stricter modulus handling  Deflectometer or compliance correction, specimen depth, setup details 
ASTM D695  Compression testing of rigid plastics  Compression hardware, load range, sample support 
ASTM D882  Tensile testing of thin films and sheets  Low-force handling, grip choice, and film-specific specimen behavior 

Once the standards are clear, force capacity becomes easier to judge. The next step is to separate useful capacity from extra capacity that may never be used.

Why Force Capacity Alone Is a Poor Buying Shortcut

Force capacity gets too much attention because it is the easiest specification to compare. A higher number looks safer and more flexible. In plastic testing, this often leads to the wrong decision. Capacity only matters in relation to the methods, materials, specimen types, and measurement requirements the lab actually has.

Many routine plastics programs fall within lower benchtop force ranges, especially when the work centers on common rigid and semi-rigid specimens. The better approach is to compare expected specimen loads against the standards, materials, and fixtures the lab actually uses instead of choosing capacity by assumption. If the lab mostly runs tensile and flexural tests on common rigid or semi-rigid plastics, a larger frame is not automatically the better choice.

Higher capacities, such as 30 kN or 50 kN, become more relevant when the program includes reinforced plastics, composite materials, larger specimens, or more demanding fixture setups.  The same logic holds when the lab expects larger specimens, broader material coverage, or more demanding fixture setups. More capacity should come from the testing scope, not from a habit of buying extra force for reassurance.

A larger capacity rating does not improve data quality on its own. It does not fix poor gripping, weak strain measurement, incorrect fixture choice, or a mismatch between the machine and the method. In plastics work, good results depend more on low-force control, stable specimen handling, suitable extensometry where modulus matters, and a setup aligned with the standard being used.

Overbuying often starts with one visible number: maximum force. A better comparison looks at expected loads, working-range accuracy, grip and fixture needs, modulus requirements, and setup changes. Higher capacity is justified when reinforced plastics, larger specimens, tougher materials, or broader fixture requirements clearly call for it.

The Hidden Decision Points Buyers Miss: Grips, Fixtures, Extensometers, and Software

In plastic testing, the frame is only part of the system. Grips, bend fixtures, strain measurement, and software directly affect specimen handling, repeatability, and reporting. Buying errors often start when those parts are treated as secondary.

Grip choice affects slippage, specimen damage, and data consistency. Pneumatic, side-action, self-tightening, or roller-style grips may be used depending on the plastic type, specimen thickness, elongation behavior, and slip risk. The grip should match the specimen and the standard, not be added as an afterthought. 

Flexural testing also depends on span setup, specimen depth, and the selected method. For ASTM D790 and ISO 178 workflows, those details affect fixture setup and measurement conditions, so they should be defined before the machine and fixture package are finalized.

Extensometers matter when modulus and strain accuracy are part of the program. A larger frame does not solve that requirement. If the lab needs modulus-quality strain data, the strain measurement method should be specified early in the buying process.

Software affects repeatability, setup speed, and reporting. In routine lab work, that can matter as much as the machine range. Our GenTest software supports the full testing workflow with method templates, setup guidance, live curves, and reporting tools.

Different Plastics Programs Need Different Machine Logic

Plastic testing is not one fixed workflow. A lab running routine tensile tests on molded specimens needs a different configuration than a lab handling films, reinforced plastics, development samples, or mixed-use teaching work.

Routine QC labs usually need consistency more than range. Their priority is repeatable setup, stable gripping, straightforward reporting, and fast operator workflow. For that type of lab, a system that covers the required standards and load range without extra complexity is often the better fit.

Production-support labs often work under similar constraints, but speed and throughput usually carry more weight. When test data supports manufacturing decisions, method setup, reporting clarity, and repeatability from one test to the next become central. Fixture changes may be limited, but the process still has to stay efficient under daily production pressure.

R&D and formulation labs usually need more flexibility. Their work may involve a wider material mix, changing specimen types, more frequent method changes, and closer attention to modulus or strain behavior. For that type of work, grips, extensometry, fixture options, and broader method coverage become more important.

University, institutional, and other multi-user labs often need a balance between flexibility and ease of use. Different operators may run different methods on the same machine, which puts more value on clear software workflow, guided setup, and configurations that reduce operator-to-operator variation. A system can be technically capable and still be a poor fit if it is harder to run consistently across a mixed user base.

Key takeaways
What Each Plastics Lab Should Prioritize
  1. Routine QC labs need consistency more than range: repeatable setup, stable gripping and straightforward reporting.
  2. Production-support labs weigh speed and throughput, with repeatability from one test to the next.
  3. R&D and formulation labs need flexibility: grips, extensometry, fixture options and broader method coverage.
  4. University and multi-user labs need a clear software workflow and guided setup that reduce operator-to-operator variation.

Benchtop vs Floor-Standing Machines for Plastic Testing

Many routine tensile and flexural plastics programs can be handled with benchtop systems when the expected loads, specimen size, and fixture needs stay within that range. A floor-standing frame should be selected only when the application requires more capacity, clearance, or setup flexibility. More capacity can be useful, but it should not be treated as the default answer for standard plastics testing.

Option  Best Fit  Not a Good Reason to Choose It 
Benchtop  Routine plastics QC, standard tensile and flexural work, limited lab space  Fear of being “too small”
Floor-standing  Reinforced plastics, larger samples, more fixture clearance, broader application scope  Buying extra capacity just for reassurance 

The decision should come from the test program, not from frame size alone. Once the required range, clearance, fixtures, and software workflow are clear, it becomes easier to match the application to the right NG-EML series.

How NextGen NG-EML Systems Fit Plastic Testing Workflows

Once the test scope is clear, the machine choice becomes more practical. Many plastics labs do not need to start with the largest available frame. They need a system that fits the expected force range, specimen types, standards, grips, fixtures, and reporting workflow. For many applications, the NG-EML Series A and Series B are the most relevant starting points.

NG-EML Series A

NG-EML Series A single-column bench top universal testing machine for tensile, compression, and flexural testing of low-force materialsThe NG-EML Series A is a compact single-column benchtop universal testing machine for lower-force plastic testing. It fits labs that work with small plastic specimens, thin films, flexible sheets, foams, packaging materials, or routine low-load quality control work.  Its 50 N to 5 kN range makes it a practical option when the test program does not call for a larger dual-column frame.

Key fit points include:

  • 50 N to 5 kN force range
  • Single-column benchtop design
  • Suitable for tension, compression, and flexural testing
  • Practical fit for plastics, rubber, foams, films, and thin materials
  • Compact footprint for labs with limited space
  • GenTest software for method setup, live curves, and reporting

Series A makes sense when the main goal is controlled low-force testing without moving into a larger system too early. For labs focused on lighter plastic specimens or space-conscious QC work, it can provide the needed range without adding unused capacity.

NG-EML Series B

NG-EML Series B dual-column bench top universal testing machine with touchscreen interface and safety shield for precise tensile and compression testingThe NG-EML Series B is a dual-column benchtop universal testing machine for broader routine plastics testing. It fits labs that need more stiffness, more test space, and a higher force range while still keeping the system in a benchtop format. For many plastics labs running tensile, compression, and flexural methods, this is the more versatile everyday choice.

Core specifications include:

  • 100 N to 10 kN force range
  • Dual-column benchtop frame
  • Class 0.5 accuracy
  • Direct-drive servo system with closed-loop control
  • Suitable for plastics, rubber, composites, and high-performance polymers
  • Compatible with GenTest software, grips, fixtures, and extensometry options

Series B fits labs that need more flexibility than a lower-force single-column system can provide. It can be a strong match for routine ASTM D638, ISO 527-2, ASTM D790, and ISO 178 workflows when the expected loads, fixtures, and strain measurement requirements fit the system range. 

How to Decide Between Series A and Series B

Choose NG-EML Series A when the work is mainly low-force, compact, and focused on lighter plastic specimens, films, foams, or smaller samples. Choose NG-EML Series B when the lab needs a broader benchtop system for standard tensile, compression, and flexural testing across a wider range of plastics.

This comparison keeps the product choice tied to the test program. It also helps avoid one of the most common purchasing problems: paying for capacity or configuration that the lab does not actually need.

Common Buying Mistakes That Lead to Overspending

Overspending on a plastic UTM usually starts before the machine is selected. The biggest mistakes tend to come from treating frame size as the main decision and leaving the rest of the test system for later.

Common buying mistakes include:

  1. Choosing by maximum force instead of expected loads: many standard plastics programs fit within lower benchtop ranges, yet buyers may still move upward because a larger number looks safer.
  2. Leaving standards until after frame selection: ASTM D638, ISO 527-2, ASTM D790, ISO 178, ASTM D695, and ASTM D882 change specimen type, fixture needs, and measurement requirements, so they should shape the buying logic from the start.
  3. Underestimating grip and fixture requirements: poor grip selection can lead to slippage, specimen damage, or weak repeatability. Flexural testing also depends on fixture setup and span geometry, not only on the frame.
  4. Assuming crosshead data is enough in every case: when modulus and strain accuracy are part of the program, extensometry and measurement quality need to be considered early.
  5. Buying a larger capacity for a mostly benchtop plastics workflow: a higher-capacity or floor-standing frame only makes sense when specimen size, material strength, fixture space, or method range clearly requires it.
  6. Treating software as secondary: repeatability, setup speed, operator consistency, and reporting all depend on workflow control, especially in routine lab use.
  7. Planning the frame before the full test system: unnecessary cost often enters the purchase when buyers focus on machine range first and leave grips, fixtures, strain measurement, and software for later.

A Practical Selection Framework: How to Right-Size a UTM for Plastic Testing

Before choosing the machine range, the lab should answer a short set of practical questions. That makes it easier to size the system around real testing needs instead of around assumptions.

  1. What materials do you test most often?
    Rigid plastics, semi-rigid parts, reinforced plastics, films, sheets, foams, and broader mixed-material programs do not create the same demands on the system.
  2. Which standards do you run most often?
    ASTM D638, ISO 527-2, ASTM D790, ISO 178, ASTM D695, and ASTM D882 lead to different specimen formats, fixture needs, and strain measurement requirements.
  3. What loads do you actually expect?
    For many routine plastics programs, 5 kN or 10 kN already covers the real workload, while reinforced plastics or broader mixed-material work may justify more capacity.
  4. Do you need modulus-quality strain measurement?
    If modulus and strain accuracy are part of the program, extensometry and measurement quality need to be planned early.
  5. Which grips and fixtures are required?
    Tensile bars, thin films, and flexural specimens do not use the same hardware, so grip style, bend fixtures, and span geometry should be defined before the machine is narrowed down.
  6. How many operators will use the system?
    A multi-user lab usually needs more guided workflow, repeatability, and reporting control than a specialist setup with one trained operator.
  7. How often do methods change?
    A routine QC workflow may stay within a narrow setup, while R&D or mixed-use labs may switch more often between fixtures, methods, and specimen types.
  8. Do you need broader flexibility or mainly routine plastics QC?
    Some labs need a system for standard plastics quality control, while others need room for reinforced materials, changing methods, or wider development work.

A quick way to narrow the choice:

  • If your lab mostly runs ASTM D638 or ASTM D790 on common rigid plastics, a lower-capacity benchtop system may already cover the practical range.
  • If the workload includes reinforced plastics, broader fixture changes, or larger and stiffer samples, a wider dual-column range becomes easier to justify.
  • If repeatability, modulus work, and operator consistency matter as much as force range, grips, extensometry, and software should be part of the decision from the start.

Choose a Plastic Testing System That Matches the Work

The right universal testing machine for plastic testing is not the one with the highest force rating. It is the one that matches the lab’s materials, specimen forms, standards, expected loads, modulus requirements, and day-to-day workflow. A right-sized system helps control cost, supports better repeatability, and gives operators the grips, fixtures, strain measurement, and software workflow needed for reliable results.

NextGen’s NG-EML line fits that approach because it is built as a range rather than a one-size-fits-all answer. With the right combination of machine range, GenTest software, grips, fixtures, and extensometry options, plastics labs can support routine QC, development work, and broader application needs without overbuying. If your lab is reviewing its current setup or planning a new plastics testing system, NextGen can help match the right UTM configuration to your materials, standards, workflow, and testing requirements.

More on this topic

Keep Reading in Electromechanical Universal Testing Machines for Plastic Testing

See the Electromechanical Universal Testing Machines for Plastic Testing range
Electromechanical Universal Testing Machines for Plastic Testing7 Jun 2021Essential Factors for Calibrating a Universal Testing Machine (UTM)There are several factors that you need to consider when you calibrate a Universal Testing Machine (UTM). During this process, you need to validate how accurate your UTM instruments are. You need to determine if you need calibration in compression or tension. Maybe you need to do it on both. The instruments used for measuring force and achieving displacement also need to be inspected and calibrated. The load size of the machine will also need to be determined. You will also have to determine if you need an extensometer calibration. When it comes to calibration, the performance of a UTM that is being tested is compared to another machine that has already passed calibration. The results are measured against a particular standard, such as those from...Read the articleElectromechanical Universal Testing Machines for Plastic Testing9 Oct 2019The Importance of an Extensometer in Materials TestingAn extensometer is an accessory to a tensile strength tester and is extensively used in materials testing. This instrument places a sample under stress, which causes it to physically deform. These deformities can be almost invisible to the eye or they can be clearly visible. Extensometry is the practice of measuring these differences. These devices are used in the Tensile Preparation ASTM E8 test along with tensile testers. ASTM E8 method is the most common test for tensile strength of metals in any form. The tests are conducted at an ambient temperature range of 50 – 100 degrees Fahrenheit (10 – 38 degrees Celsius). Although the ATSM E8 tensile test is designed to measure a range of different properties, the following are the most common: Yield...Read the articleElectromechanical Universal Testing Machines for Plastic Testing25 Oct 2026How to Perform a Tensile Test on Metals: Step by Step to ASTM E8/E8M and ISO 6892-1A tensile test looks simple from across the laboratory. A specimen goes into the grips, the crosshead moves, the specimen stretches and breaks, and the software prints a few numbers. Most of what decides whether those numbers are right happens before the first newton of force: how the specimen was machined and measured, where the gauge marks sit, how the specimen hangs in the grips, which extensometer is on it and how fast the machine is told to pull. This guide walks through a room-temperature tensile test on metal in the order a laboratory performs it, following the two standards most reports are written against, ASTM E8/E8M and ISO 6892-1. Where the two differ, it says so, because a result is only comparable with another result obtained under the...Read the articlePlastic Testing18 Oct 2026Shore Durometer Hardness to ASTM D2240: Choosing the Scale, Reading the Number and Why Two Durometers DisagreeShore hardness is the number most rubber and plastic specifications quote first, and it is also the number most likely to start an argument between a supplier and a customer. Two instruments, both calibrated, both from reputable makers, read the same part three or four points apart, and each side is sure the other one is wrong. Most of the time neither instrument is broken. The two readings were taken under conditions the standard leaves open, and the difference was written into the number before anyone looked at the display. This guide works through ASTM D2240 and its ISO counterparts in the order a laboratory meets them: what a durometer measures, which of the twelve types fits a material, why one scale does not translate into another, how the...Read the articlePlastic Testing9 Oct 2026HDT and Vicat: Two Softening Temperatures That Answer Different QuestionsMost thermoplastic datasheets carry two temperatures that sound like the same idea. One is the heat deflection temperature, HDT, and the other is the Vicat softening temperature, VST. Both are measured in a heated bath, both are reported as a single number in degrees, and both get used, sooner or later, as if they were the temperature at which the part stops working. Neither one is that, and they are not two readings of the same property either. The difference starts with what the specimen is being asked to do while the bath heats up. Once that is clear, the rest follows: why the two values sit at different temperatures, why an ISO and an ASTM HDT for the same grade are not interchangeable, and which details of the test quietly move each result....Read the articlePlastic Testing5 Aug 2026Vicat Testing and What Cement Setting Time Really Tells YouVicat setting time is a standardized cement paste measurement used for specification compliance and quality control. It identifies when a paste prepared under defined conditions reaches the initial and final set criteria of the selected method. It does not directly predict concrete haul time, cold joint formation, finishing time or field workability, because those depend on the complete mixture: water content, admixtures, aggregates and temperature. This guide covers what Vicat setting time measures, how the apparatus produces the number, which test conditions make results drift, and what separates a manual instrument from an automatic one. Setting Time Is Not Early Strength Initial and final set describe the stiffening of a standardized cement...Read the articleElectromechanical Universal Testing Machines for Plastic Testing4 Jan 2026GenTest 3.0: Test Control And Data Acquisition Software For NextGen UTMsHow much time does your lab spend after the test: rebuilding methods, double-checking signals, and turning raw data into a report you can actually use? In QA/QC and repeatable R&D work, the bottleneck is usually everything around the run: method setup, in-test visibility, and producing traceable results without extra cleanup. GenTest 3.0 is NextGen Material Testing’s software environment for NextGen universal testing machines, including both electromechanical and servo-hydraulic systems. It brings test execution, live data capture, built-in calculations, and reporting into a single workflow, so labs can move from setup to final documentation without patching together spreadsheets, screenshots, and manual report edits. For teams running QA and QC...Read the articlePlastic Testing6 Aug 2025Most Popular DIN Standards in Material TestingStandards keep material tests readable across labs and borders. Among the major families you’ll run into in day-to-day work, DIN standards from the German Institute for Standardization (Deutsches Institut für Normung) are especially visible. Many have been harmonized with European and international practices, so data produced according to DIN often translates cleanly across markets. In this article, we break down 13 commonly used DIN standards in material testing. For each one, we explain what the method measures, typical specimens and conditions, the kind of equipment it’s run on, and where it’s most often applied. Where applicable, we’ll point to close ISO or ASTM counterparts and highlight practical differences that can impact results, such as...Read the articlePlastic Testing22 Jun 20255 Reasons Impact Testing Is a Must for Exterior Automotive ComponentsThousands of road accidents occur each day on a global scale. Some of them are inconsequential, while others result in severe vehicle damage or personal injury. In all these situations, the exterior parts of a vehicle are the first to face the impact. That is why industrial impact testing of exterior automotive components is a must. Manufacturers understand that accidents are always possible. To prepare, they test components such as bumpers, body panels, headlight housings, and plastic trims. These tests assist in predicting the behavior of each component in the event of a collision. Engineers make decisions regarding materials, design, and safety features in order to mitigate potential damage, based on the results. While safety is the primary...Read the article
Related equipment

Machines Behind This Article

NG-EML Series A – Single-Column Universal Testing Machine (50 N – 5 kN)Electromechanical Universal Testing Machines for Plastic TestingNG-EML Series A – Single-Column Universal Testing Machine (50 N – 5 kN)NG-EML Series A is a compact single-column benchtop universal testing machine for low-force tensile, compression, and flexural testing. Covering 50 N to 5 kN...View productNG-EML Series B – Dual-Column Universal Testing Machine (100 N – 10 kN)Electromechanical Universal Testing Machines for Plastic TestingNG-EML Series B – Dual-Column Universal Testing Machine (100 N – 10 kN)NG-EML Series B is a dual-column benchtop electromechanical universal testing machine for precision testing from 100 N to 10 kN. Built for research and industrial...View productNG-EML Series C – Dual-Column Universal Testing Machine (5–50 kN)Electromechanical Universal Testing Machines for Plastic TestingNG-EML Series C – Dual-Column Universal Testing Machine (5–50 kN)NG-EML Series C is a dual-column electromechanical universal testing machine available in bench-top and floor-standing formats from 5 kN to 50 kN. Built for...View productNG-EML Series D – Floor-Standing Universal Testing Machine (50–1000 kN)Electromechanical Universal Testing Machines for Plastic TestingNG-EML Series D – Floor-Standing Universal Testing Machine (50–1000 kN)NG-EML Series D is a heavy-duty floor-standing electromechanical universal testing machine for high-capacity tensile, compression, and flexural testing. Available...View product3-Point Bending Fixtures for Flexural TestingGrips and Fixtures for NextGen Universal Testing Machines (UTMs)3-Point Bending Fixtures for Flexural TestingThese bending fixtures support standard 3-point flexural testing of plastics, composites, metals, ceramics, alloys, and construction materials. Designed for use...View productTestStar Series Grips and Fixtures for Hydraulic UTMsGrips and Fixtures for NextGen Universal Testing Machines (UTMs)TestStar Series Grips and Fixtures for Hydraulic UTMsTestStar® Series grips and fixtures are high-precision accessories for integrating tensile, snubbing, wedge-action, pneumatic, compression, and bending setups with...View productShoulder Fixtures for Pull-Off TestingGrips and Fixtures for NextGen Universal Testing Machines (UTMs)Shoulder Fixtures for Pull-Off TestingShoulder fixtures are specialized tensile grips for specimens and components with shoulder geometries, where alignment and secure seating are essential for reliable...View productCompression Fixtures for Rigid SamplesGrips and Fixtures for NextGen Universal Testing Machines (UTMs)Compression Fixtures for Rigid SamplesCompression fixtures provide aligned axial loading for rigid samples tested on NG-EML and SHM universal testing machines. They are suited for metals, polymers,...View productAlignment Device – NADCAP-Ready Precision FixtureUniversal Testing Machines for Metal TestingAlignment Device – NADCAP-Ready Precision FixtureThe Alignment Device is a NADCAP-ready precision fixture for verifying and correcting load-frame alignment on universal and fatigue testing machines. Designed to...View productGenTest – Advanced UTM Testing SoftwareElectromechanical Universal Testing Machines for Plastic TestingGenTest – Advanced UTM Testing SoftwareGenTest is NextGen’s advanced UTM testing software for electromechanical universal testing machines, managing test setup, live control, data acquisition,...View product